;0x1200 Modbus通用测试用 [comm] debug=1 ;打开调试输出信息 默认0(不打开) delay=500 ;采集指令延时,单位 ms 默认10 mask=0 ;保留 model=OM-MDBS4930 ;型号 添加支持类型用 note=Cyber; DME优化MODBUS通讯协议(V1.2)空调协议.pdf brief=室内回风温度: %64% ℃ %64st%,室内回风湿度: %65% % %65st% [regs2] 1=100 130=20 [regs4] 0=20 [flds] cnt=67 1=10003;回风高温 2=10004;回风低温 3=10005;回风高湿 4=10006;回风低湿 5=10007;送风高温 6=10008;送风低温 7=10009;烟雾报警 8=10010;水浸报警 9=10011;排水故障 10=10018;A相过电压 11=10019;B相过电压 12=10020;C相过电压 13=10021;A相欠电压 14=10022;B相欠电压 15=10023;C相欠电压 16=10024;三相不平衡 17=10025;电源频率超下限 18=10026;电源频率超上限 19=10027;A相缺相 20=10028;B相缺相 21=10029;C相缺相 22=10030;电源错相 23=10034;内风机1故障 24=10035;内风机2故障 25=10036;内风机3故障 26=10037;气流丢失 27=10038;过滤网堵塞 28=10044;压缩机1高压告警 29=10045;压缩机1高压告警锁定 30=10046;压缩机1低压告警 31=10047;压缩机1低压告警锁定 32=10048;压缩机1排气高温 33=10049;压缩机1排气高温锁定 34=10050;压缩机1频率异常 35=10051;压缩机1频率异常锁定 36=10056;外风机1告警 37=10063;压缩机2高压告警 38=10064;压缩机2高压告警锁定 39=10065;压缩机2低压告警 40=10066;压缩机2低压告警锁定 41=10067;压缩机2排气高温 42=10068;压缩机2排气高温锁定 43=10069;压缩机2频率异常 44=10070;压缩机2频率异常锁定 45=10075;外风机2告警 46=10133;加湿器故障 47=10134;加湿电流检测故障 48=10135;加湿桶排水阀故障 49=10136;湿膜低水位 50=10137;水位开关故障 51=10138;缺水故障 52=10031;内风机1状态 53=10032;内风机2状态 54=10033;内风机3状态 55=10055;外风机1状态 56=10074;外风机2状态 57=10042;压缩机1状态 58=10061;压缩机2状态 59=10132;加湿器状态 60=10145;加热器1状态 61=10146;加热器2状态 62=30003;温度设定值 63=30004;湿度设定值 64=30006;室内回风温度 65=30007;室内回风湿度 66=30015;机组状态 67=30016;运行模式 [flds.def] ;x=FldName,FldDept,Note,vkind,vfactor,vmode,vref,vtip,vref2,vtip2 1='Fld',1,'回风高温',0,1,0,0,'0:正常,1:故障',0,'' 2='Fld',1,'回风低温',0,1,0,0,'0:正常,1:告警',0,'' 3='Fld',1,'回风高湿',0,1,0,0,'0:正常,1:告警',0,'' 4='Fld',1,'回风低湿',0,1,0,0,'0:正常,1:告警',0,'' 5='Fld',1,'送风高温',0,1,0,0,'0:正常,1:告警',0,'' 6='Fld',1,'送风低温',0,1,0,0,'0:正常,1:告警',0,'' 7='Fld',1,'烟雾报警',0,1,0,0,'0:正常,1:告警',0,'' 8='Fld',1,'水浸报警',0,1,0,0,'0:正常,1:告警',0,'' 9='Fld',1,'排水故障',0,1,0,0,'0:正常,1:告警',0,'' 10='Fld',1,'A相过电压',0,1,0,0,'0:正常,1:告警',0,'' 11='Fld',1,'B相过电压',0,1,0,0,'0:正常,1:告警',0,'' 12='Fld',1,'C相过电压',0,1,0,0,'0:正常,1:告警',0,'' 13='Fld',1,'A相欠电压',0,1,0,0,'0:正常,1:告警',0,'' 14='Fld',1,'B相欠电压',0,1,0,0,'0:正常,1:告警',0,'' 15='Fld',1,'C相欠电压',0,1,0,0,'0:正常,1:告警',0,'' 16='Fld',1,'三相不平衡',0,1,0,0,'0:正常,1:告警',0,'' 17='Fld',1,'电源频率超下限',0,1,0,0,'0:正常,1:告警',0,'' 18='Fld',1,'电源频率超上限',0,1,0,0,'0:正常,1:告警',0,'' 19='Fld',1,'A相缺相',0,1,0,0,'0:正常,1:告警',0,'' 20='Fld',1,'B相缺相',0,1,0,0,'0:正常,1:告警',0,'' 21='Fld',1,'C相缺相',0,1,0,0,'0:正常,1:告警',0,'' 22='Fld',1,'电源错相',0,1,0,0,'0:正常,1:告警',0,'' 23='Fld',1,'内风机1故障',0,1,0,0,'0:正常,1:告警',0,'' 24='Fld',1,'内风机2故障',0,1,0,0,'0:正常,1:告警',0,'' 25='Fld',1,'内风机3故障',0,1,0,0,'0:正常,1:告警',0,'' 26='Fld',1,'气流丢失',0,1,0,0,'0:正常,1:告警',0,'' 27='Fld',1,'过滤网堵塞',0,1,0,0,'0:正常,1:告警',0,'' 28='Fld',1,'压缩机1高压告警',0,1,0,0,'0:正常,1:告警',0,'' 29='Fld',1,'压缩机1高压告警锁定',0,1,0,0,'0:正常,1:告警',0,'' 30='Fld',1,'压缩机1低压告警',0,1,0,0,'0:正常,1:告警',0,'' 31='Fld',1,'压缩机1低压告警锁定',0,1,0,0,'0:正常,1:告警',0,'' 32='Fld',1,'压缩机1排气高温',0,1,0,0,'0:正常,1:告警',0,'' 33='Fld',1,'压缩机1排气高温锁定',0,1,0,0,'0:正常,1:告警',0,'' 34='Fld',1,'压缩机1频率异常',0,1,0,0,'0:正常,1:告警',0,'' 35='Fld',1,'压缩机1频率异常锁定',0,1,0,0,'0:正常,1:告警',0,'' 36='Fld',1,'外风机1告警',0,1,0,0,'0:正常,1:告警',0,'' 37='Fld',1,'压缩机2高压告警',0,1,0,0,'0:正常,1:告警',0,'' 38='Fld',1,'压缩机2高压告警锁定',0,1,0,0,'0:正常,1:告警',0,'' 39='Fld',1,'压缩机2低压告警',0,1,0,0,'0:正常,1:告警',0,'' 40='Fld',1,'压缩机2低压告警锁定',0,1,0,0,'0:正常,1:告警',0,'' 41='Fld',1,'压缩机2排气高温',0,1,0,0,'0:正常,1:告警',0,'' 42='Fld',1,'压缩机2排气高温锁定',0,1,0,0,'0:正常,1:告警',0,'' 43='Fld',1,'压缩机2频率异常',0,1,0,0,'0:正常,1:告警',0,'' 44='Fld',1,'压缩机2频率异常锁定',0,1,0,0,'0:正常,1:告警',0,'' 45='Fld',1,'外风机2告警',0,1,0,0,'0:正常,1:告警',0,'' 46='Fld',1,'加湿器故障',0,1,0,0,'0:正常,1:告警',0,'' 47='Fld',1,'加湿电流检测故障',0,1,0,0,'0:正常,1:告警',0,'' 48='Fld',1,'加湿桶排水阀故障',0,1,0,0,'0:正常,1:告警',0,'' 49='Fld',1,'湿膜低水位',0,1,0,0,'0:正常,1:告警',0,'' 50='Fld',1,'水位开关故障',0,1,0,0,'0:正常,1:告警',0,'' 51='Fld',1,'缺水故障',0,1,0,0,'0:正常,1:告警',0,'' 52='Fld',1,'内风机1状态',0,1,0,0,'0:正常,1:告警',0,'' 53='Fld',1,'内风机2状态',0,1,0,0,'0:正常,1:告警',0,'' 54='Fld',1,'内风机3状态',0,1,0,0,'0:关,1:开',0,'' 55='Fld',1,'外风机1状态',0,1,0,0,'0:关,1:开',0,'' 56='Fld',1,'外风机2状态',0,1,0,0,'0:关,1:开',0,'' 57='Fld',1,'压缩机1状态',0,1,0,0,'0:关,1:开',0,'' 58='Fld',1,'压缩机2状态',0,1,0,0,'0:关,1:开',0,'' 59='Fld',1,'加湿器状态',0,1,0,0,'0:关,1:开',0,'' 60='Fld',1,'加热器1状态',0,1,0,0,'0:关,1:开',0,'' 61='Fld',1,'加热器2状态',0,1,0,0,'0:关,1:开',0,'' 62='Fld',1,'温度设定值',0,10,11,100,'最小值|允许最低值',350,'最大值|允许最高值' 63='Fld',1,'湿度设定值',0,10,11,100,'最小值|允许最低值',750,'最大值|允许最高值' 64='Fld',1,'室内回风温度',0,10,11,100,'最小值|允许最低值',350,'最大值|允许最高值' 65='Fld',1,'室内回风湿度',0,10,11,100,'最小值|允许最低值',750,'最大值|允许最高值' 66='Fld',1,'机组状态',0,1,0,0,'0:本地关机,1:开机,2:故障关机,3:群组待机,4:关机中,5:远程关机',0,''