[comm] debug=1 ;打开调试输出信息 默认0(不打开) delay=50 ;采集指令延时,单位 ms 默认10 mask=0 ;保留 model=OM-MDBS4939 ;型号 添加支持类型用 note= brief=市电电压: %17% V %18% V %19% V ,U电电压: %40% V %41% V %42% V , [regs1] 0=20 ; [regs3] 0=60 [flds] cnt=62 1=00001;市电A相电压异常报警 2=00002;市电B相电压异常报警 3=00003;市电C相电压异常报警 4=00004;市电A相电流过载报警 5=00005;市电B相电流过载报警 6=00006;市电C相电流过载报警 7=00007;U电A相电压异常报警 8=00008;U电B相电压异常报警 9=00009;U电C相电压异常报警 10=00010;U电A相电流过载报警 11=00011;U电B相电流过载报警 12=00012;U电C相电流过载报警 13=00014;市电总开开关状态 14=00015;UPS输入开关状态 15=00016;UPS维修旁路开关状态 16=00017;UPS输出开关状态 17=40001;市电A相电压 18=40002;市电B相电压 19=40003;市电C相电压 20=40004;市电A相电流 21=40005;市电B相电流 22=40006;市电C相电流 23=40007;市电三相有功 24=40008;市电A相有功功率 25=40009;市电B相有功功率 26=40010;市电C相有功功率 27=40011;市电三相无功 28=40012;市电A相无功功率 29=40013;市电B相无功功率 30=40014;市电C相无功功率 31=40015;市电三相视在 32=40016;市电A相视在功率 33=40017;市电B相视在功率 34=40018;市电C相视在功率 35=40019;市电总功因数 36=40020;市电频率 37=40021;市电A相负载率 38=40022;市电B相负载率 39=40023;市电C相负载率 40=40031;U电A相电压 41=40032;U电B相电压 42=40033;U电C相电压 43=40034;U电A相电流 44=40035;U电B相电流 45=40036;U电C相电流 46=40037;U电三相有功 47=40038;U电A相有功功率 48=40039;U电B相有功功率 49=40040;U电C相有功功率 50=40041;U电三相无功 51=40042;U电A相无功功率 52=40043;U电B相无功功率 53=40044;U电C相无功功率 54=40045;U电视在功率 55=40046;U电A相视在功率 56=40047;U电B相视在功率 57=40048;U电C相视在功率 58=40049;U电总功因数 59=40050;U电A相频率 60=40051;U电A相负载率 61=40052;U电B相负载率 62=40053;U电C相负载率 [flds.def] ;x=FldName,FldDept,Note,vkind,vfactor,vmode,vref,vtip,vref2,vtip2 1='Fld',1,'市电A相电压异常报警',0,1,0,0,'0:正常,1:告警',0,'' 2='Fld',1,'市电B相电压异常报警',0,1,0,0,'0:正常,1:告警',0,'' 3='Fld',1,'市电C相电压异常报警',0,1,0,0,'0:正常,1:告警',0,'' 4='Fld',1,'市电A相电流过载报警',0,1,0,0,'0:正常,1:告警',0,'' 5='Fld',1,'市电B相电流过载报警',0,1,0,0,'0:正常,1:告警',0,'' 6='Fld',1,'市电C相电流过载报警',0,1,0,0,'0:正常,1:告警',0,'' 7='Fld',1,'U电A相电压异常报警',0,1,0,0,'0:正常,1:告警',0,'' 8='Fld',1,'U电B相电压异常报警',0,1,0,0,'0:正常,1:告警',0,'' 9='Fld',1,'U电C相电压异常报警',0,1,0,0,'0:正常,1:告警',0,'' 10='Fld',1,'U电A相电流过载报警',0,1,0,0,'0:正常,1:告警',0,'' 11='Fld',1,'U电B相电流过载报警',0,1,0,0,'0:正常,1:告警',0,'' 12='Fld',1,'U电C相电流过载报警',0,1,0,0,'0:正常,1:告警',0,'' 13='Fld',1,'市电总开开关状态',0,1,0,0,'0:正常,1:告警',0,'' 14='Fld',1,'UPS输入开关状态',0,1,0,0,'0:正常,1:告警',0,'' 15='Fld',1,'UPS维修旁路开关状态',0,1,0,0,'0:正常,1:告警',0,'' 16='Fld',1,'UPS输出开关状态',0,1,0,0,'0:正常,1:告警',0,'' 17='Fld',1,'市电A相电压',0,10,11,1900,'最小值|最小允许值',2550,'最大值|最大允许值' 18='Fld',1,'市电B相电压',0,10,11,1900,'最小值|最小允许值',2550,'最大值|最大允许值' 19='Fld',1,'市电C相电压',0,10,11,1900,'最小值|最小允许值',2550,'最大值|最大允许值' 37='Fld',1,'市电A相负载率',0,10,11,0,'最小值|最小允许值',300,'最大值|最大允许值' 38='Fld',1,'市电B相负载率',0,10,11,0,'最小值|最小允许值',300,'最大值|最大允许值' 39='Fld',1,'市电C相负载率',0,10,11,0,'最小值|最小允许值',300,'最大值|最大允许值' 40='Fld',1,'U电A相电压',0,10,11,1900,'最小值|最小允许值',2550,'最大值|最大允许值' 41='Fld',1,'U电B相电压',0,10,11,1900,'最小值|最小允许值',2550,'最大值|最大允许值' 42='Fld',1,'U电C相电压',0,10,11,1900,'最小值|最小允许值',2550,'最大值|最大允许值' 60='Fld',1,'U电A相负载率',0,10,11,0,'最小值|最小允许值',300,'最大值|最大允许值' 61='Fld',1,'U电B相负载率',0,10,11,0,'最小值|最小允许值',300,'最大值|最大允许值' 62='Fld',1,'U电C相负载率',0,10,11,0,'最小值|最小允许值',300,'最大值|最大允许值' [vals.str] Name=1 [vals.ext] Stor.5=1 ;[vals]