;0x1400 YD电总通用测试用 [comm] debug=1 ;打开调试输出信息 默认0(不打开) delay=50 ;采集指令延时,单位 ms 默认10 mask=0 ;保留 model=OM-YD5120 ;型号 添加支持类型用 note=测试通用电总协议 ;说明 添加支持类型用 brief=PACK电流:: %1% A,PACK总电压: %22% V,PACK剩余容量:%23% AH ;简报 %x%为某字段值 简报中不能带分号; bak=1 ver=25 ;空则自动获取? cid1=60;不是60H,不用加H cid2=42H47H82H [42H];模拟量化数据 dflag=1 dinfo=I dfac=1 [47H];系统运行状态 dflag=1 dinfo=I dfac=1 [82H];告警信息 dflag=1 dinfo=S dfac=1 [flds] cnt=37 ;模拟量 1=42H01;室内温度 2=42H02;室内湿度 3=42H03;A相电压 4=42H04;B相电压 5=42H05;C相电压 6=42H06;加湿器电流 7=42H07;电源频率 ;基本参数 8=47H01;回风温度设定点 9=47H02;湿度设定点 10=47H03;温度偏差 11=47H04;湿度偏差 12=47H05;温度死区 13=47H06;湿度死区 14=47H07;高温告警值 15=47H08;低温告警值 16=47H09;高湿告警值 17=47H10;低湿告警值 18=47H11;送风高温告警值 19=47H12;送风温度设定点 ;空调开关输出状态 20=82H01;空调开关机状态 21=82H02;风机输出开关状态 22=82H03;加湿器输出开关状态 23=82H04;压缩机1输出开关状态 24=82H05;压缩机2输出开关状态 25=82H06;加热1输出开关状态 26=82H07;加热2输出开关状态 27=82H08;公共报警输出开关状态 28=82H09;液路旁通1输出开关状态 29=82H10;液路旁通2输出开关状态 30=82H11;注水输出开关状态 31=82H12;除湿输出开关状态 32=82H14;压缩机1反相输出开关状态 33=82H15;压缩机2反相输出开关状态 34=82H16;制冷状态 35=82H17;加热状态 36=82H18;除湿状态 37=82H19;加湿状态 [flds.def] ;x=FldName,FldDept,Note,vkind,vfactor,vmode,vref,vtip,vref2,vtip2 1='Fld',1,'室内温度',0,10,11,200,'最小值|允许最低值.',350,'最大值|允许最高值' 1='Fld1',1,'室内温度',0,10,0,0,'',0,'' 2='Fld2',1,'室内湿度',0,10,0,0,'',0,'' 3='Fld3',1,'A相电压',0,1,0,0,'',0,'' 4='Fld4',1,'B相电压',0,1,0,0,'',0,'' 5='Fld5',1,'C相电压',0,1,0,0,'',0,'' 6='Fld6',1,'加湿器电流',0,1,0,0,'',0,'' 7='Fld7',1,'电源频率',0,1,0,0,'',0,'' 8='Fld8',1,'回风温度设定点',0,10,0,0,'',0,'' 9='Fld9',1,'湿度设定点',0,10,0,0,'',0,'' 10='Fld10',1,'温度偏差',0,10,0,0,'',0,'' 11='Fld11',1,'湿度偏差',0,10,0,0,'',0,'' 12='Fld12',1,'温度死区',0,10,0,0,'',0,'' 13='Fld13',1,'湿度死区',0,10,0,0,'',0,'' 14='Fld14',1,'高温告警值',0,10,0,0,'',0,'' 15='Fld15',1,'低温告警值',0,10,0,0,'',0,'' 16='Fld16',1,'高湿告警值',0,10,0,0,'',0,'' 17='Fld17',1,'低湿告警值',0,10,0,0,'',0,'' 18='Fld18',1,'送风高温告警值',0,10,0,0,'',0,'' 19='Fld19',1,'送风温度设定点',0,10,0,0,'',0,'' 20='Fld20',1,'空调开关机状态',0,1,0,0,'0:运行; 1:待机; 2:关机; 3:远程关机;',0,'' 21='Fld21',1,'风机输出开关状态',0,1,0,0,'0:关,1:开',0,'' 22='Fld22',1,'加湿器输出开关状态',0,1,0,0,'0:关,1:开',0,'' 23='Fld23',1,'压缩机1输出开关状态',0,1,0,0,'0:关,1:开',0,'' 24='Fld24',1,'压缩机2输出开关状态',0,1,0,0,'0:关,1:开',0,'' 25='Fld25',1,'加热1输出开关状态',0,1,0,0,'0:关,1:开',0,'' 26='Fld26',1,'加热2输出开关状态',0,1,0,0,'0:关,1:开',0,'' 27='Fld27',1,'公共报警输出开关状态',0,1,0,0,'0:关,1:开',0,'' 28='Fld28',1,'液路旁通1输出开关状态',0,1,0,0,'0:关,1:开',0,'' 29='Fld29',1,'液路旁通2输出开关状态',0,1,0,0,'0:关,1:开',0,'' 30='Fld30',1,'注水输出开关状态',0,1,0,0,'0:关,1:开',0,'' 31='Fld31',1,'除湿输出开关状态',0,1,0,0,'0:关,1:开',0,'' 32='Fld32',1,'压缩机1反相输出开关状态',0,1,0,0,'0:关,1:开',0,'' 33='Fld33',1,'压缩机2反相输出开关状态',0,1,0,0,'0:关,1:开',0,'' 34='Fld34',1,'制冷状态',0,1,0,0,'0:关,1:开',0,'' 35='Fld35',1,'加热状态',0,1,0,0,'0:关,1:开',0,'' 36='Fld36',1,'除湿状态',0,1,0,0,'0:关,1:开',0,'' 37='Fld37',1,'加湿状态',0,1,0,0,'0:关,1:开',0,''